Greenstar displays often show two numbers, a letter code and a cause code. Read us both if you can see both.
No heating or hot water right now? Call 0203 868 6134. We will tell you the earliest realistic slot rather than the one you want to hear.
Two details to start. Add the fault code and your postcode and we can usually tell you the likely part before we attend.

Three steps, no sales pitch, and you will know where you stand before an engineer is booked.
The expensive mistake on a Worcester is replacing the part the code named. An E9 is rarely the thermostat and an EA is rarely the board, because in both cases the part shown is the one reporting the problem rather than causing it. We test before we quote, and there is no charge for telling you on the phone that the part you were quoted for is not the one that failed.

Worcester failures cluster tightly. Six parts account for most of what we attend, and five of them are tied to a specific code.
A Greenstar shows a letter code and, on most models, a cause code beside it. The pair is what identifies the fault. EA on its own could be four different things. EA with 227 is one fault and EA with 229 is another, and they are repaired differently.
What the boiler is saying: it could not detect a flame through the ionisation probe, so it shut the gas off and stopped.
Read the number beside it. EA 227 means no flame was detected after ignition, so it never lit. EA 229 means a flame was established and then lost part way through. Same two letters, two different investigations.
What 227 usually is: the flame sensing electrode and its lead, carboned at the tip so the signal never reaches the board. Then the ignition lead, then the gas valve.
What 229 usually is: the gas to air ratio, the dynamic gas pressure at the appliance, or flue products recirculating into the air intake. Parts rarely fix a 229.
Rarely the cause: the circuit board. It was doing its job by locking out rather than continuing to release gas into a boiler that was not burning it.
Check first: does anything else in the house run on gas? A hob that will not light points at the supply. In winter, check the plastic condensate pipe outside for ice.
Reading EA right now? Tell us the three digit number next to it.
The water in the primary circuit went past the limit the safety thermostat allows, so the burner shut down. On most Greenstar models this appears as E9 224.
The likely cause: circulation, not the burner. Sludge, a seized or closed valve, a tired pump or a pocket of trapped air. The boiler is producing heat faster than the system is carrying it away, so it cooks in one spot.
Rarely the cause: the heat exchanger, which is what people fear when they hear overheat. It is the last thing to suspect, not the first.
Why swapping the thermostat rarely works: the limiter is the part reporting the problem. Replace it and leave the circulation alone and it will trip again, because it is still measuring the same water.
What helps most: not a part at all. Clearing the system of sludge addresses the cause where a component swap usually does not.
An overheat lockout. Leave it off and tell us what the pressure gauge reads.
The board asks the fan for a speed and reads back what it actually achieved. When the two do not match closely enough, it stops.
The likely cause: the fan itself. The bearing wears, and on a Greenstar this almost always announces itself first. If the boiler has been noisier than it used to be for a few weeks, that is the same fault earlier on.
Rarely the cause: only the fan. A flue that is partly blocked, or a terminal packed with leaves or nesting material, makes a healthy fan work against resistance the board reads as a fault. Checking the flue costs nothing and a fan does not.
Worth knowing: a fan that has been noisy and then goes quiet has not repaired itself. It has usually stopped.
Has it been noisy lately? That detail narrows this down.
Shown on the newer Greenstar i and 8000 range. Older models say nothing at all and simply refuse to fire, which is why people assume the boiler has died when the gauge is the whole story.
What you can safely do: top up through the filling loop until the gauge reads between 1 and 1.5 bar cold, then reset once. This is one of the few Worcester codes a householder can clear.
Rarely the cause: a boiler fault. The boiler is reporting the system, not itself.
Topping up more than once a month? Tell us before you refill it again.
Usually shown as A1 281. The boiler asked the pump to move water and did not see the result it expected.
The likely cause: a pump seized after a long summer standing still, or a system with enough air in it that the pump is spinning in a void. The second is far more common in spring after nobody has bled a radiator since October.
Rarely the cause: a reason to replace the whole pump body. On Greenstar models the head unbolts from the body, so the wet side of the system stays sealed and the job is shorter and cheaper than most people are quoted for.
Related: A1 and E9 often arrive within days of each other, because a pump that has stopped moving water is also the reason the water is overheating.
Can you hear anything at all from the boiler when heating calls?
A condensing boiler makes about two litres of mildly acidic water a day and has to get rid of it. When it cannot, it stops.
What you can safely do: in cold weather, pour warm water along the plastic pipe that runs from the boiler to an outside drain. Warm, never boiling, which splits it.
What it usually is when the weather is mild: the siphon inside the boiler rather than the pipe outside. Worcester use a siphon that holds a small volume of water as a seal, and debris settles in the bottom of it over the years.
One thing to check: on some CDi models D5 is a service reminder rather than a fault, so it is worth confirming which your model does before anybody charges you to attend.
Is it freezing outside, or has this started in mild weather?
The opposite fault to EA. The board closed the gas valve and then carried on reading a flame signal, so it locked out.
The likely cause: moisture or condensation tracking across the electrode or its connector, giving a false reading, or the sensing lead sitting where it should not be. Occasionally the gas valve is passing.
Rarely the cause: something to keep resetting. This is a gas safety lockout and the boiler is refusing to run for a reason worth respecting.
Why it matters more than the others: most codes mean the boiler stopped when it should have. This one means the boiler saw something it could not explain, which is a different order of problem and not one to sit on.
Leave it switched off at the fused spur and call us.
The shape of the code tells you which generation of Worcester you own, and it is the reason so many people look up a code and find an answer that does not fit their boiler.
Letters, or letters with a three digit number: EA, E9, C6, A1. This is the CDi Classic, the CDi Compact and the Greenstar i.
Bare numbers with a letter suffix, such as 227 V or 1017 W: the Greenstar 8000 range and the GB162. The number means something completely different here, so a generic list written for the older display will send you the wrong way.
No display, only a light: the Greenstar Ri and the older CDi Highflow report by flashing an indicator, and the pattern is the code.
T1 through T6: not a fault at all. Somebody has left the boiler in component test mode after a service.
| Code | What the boiler is saying | What it usually turns out to be |
|---|---|---|
| b1 | Code plug not detected | A board changed without moving the plug across |
| A7 | Hot water sensor fault | The sensor or its plug, not the heat exchanger |
| A8 | Communication lost, or pressure too high on some models | A control wire, or a filling loop left open |
| CE 203 | Flow sensor reading out of range | The sensor and its wiring, not the water |
| E2 | Central heating flow sensor fault | A chafed harness more often than a dead sensor |
| FD | Wording varies between models | Look this one up in your own manual, not a generic list |
| F0 | Internal error | The board, and only after everything else clears |
| T1 to T6 | Component test running | Not a fault. An engineer left it in test mode |
Every Greenstar carries a small code plug on its control board, and that plug is what tells a generic board which appliance it has been fitted to. Change the board without moving the plug across and the boiler shows b1 and will not run, no matter how new the board is. It is a two second job that is easy to forget, and it is worth asking about if a boiler has stopped working immediately after somebody replaced the electronics.
Plenty of Greenstar problems never put anything on the display, and one whole generation of Worcester boilers has no display to put it on.
The classic Worcester hot water fault, and it is not the heat exchanger. A combi has to know the instant a tap opens, and on most Greenstar models that job belongs to a small turbine in the cold inlet.
When the turbine sticks, the boiler either does not fire at all when you open a tap, or fires late and then drops out. What you feel at the tap is water that keeps changing its mind.
How to tell it apart from scale: a scaled plate heat exchanger gives you water that is steadily lukewarm and never gets properly hot. A sticking turbine gives you water that is properly hot some of the time. Steady and disappointing is one fault, erratic is the other.
Does it ever get properly hot, or never? Call 0203 868 6134.
The Greenstar Ri and the older CDi Highflow do not have a digital display. They report faults by flashing an indicator light in a pattern, and the pattern is the code.
This catches people out badly, because a boiler with no readout looks like a boiler that has simply died. It has not. It is telling you something in a format nobody remembers how to read.
What to do: count the flashes, note whether the light is red, green or amber and whether it flashes steadily or in bursts, and tell us. That description does the same job as a code.
Describe the light and we can usually narrow it down on the phone. Call 0203 868 6134.
Intermittent is the hardest kind of fault to get taken seriously, and on a Worcester it usually has a physical explanation rather than a mysterious one.
The two usual causes are the condensate siphon, which only stops the boiler once it has filled beyond a certain point, and an electrode that fails when cold and works once the boiler has warmed through. Both produce a fault that clears on reset and comes back later, which is exactly what makes people put up with it.
Worth doing: write down the date and time each time it happens before you reset it. A pattern of early mornings points at one cause, a pattern of every four or five days regardless of time points at the other. That note is worth more than any guess we could make.
Worcester sell their own controls alongside the boiler, and a good share of no heating call-outs on newer installations turn out to be the control rather than the appliance.
A wireless thermostat with a flat battery, a controller that has lost its pairing after a power cut, or a schedule that reset itself will all produce a boiler that is in perfect health and completely idle. There is no fault code because there is no fault.
Before you book anybody: turn the heating on at the boiler itself if your model allows it, or put the control into a constant or manual override. If the boiler fires, the problem is upstream of it and the repair is a great deal smaller than you feared.
Does it fire when you override the control? Call 0203 868 6134.
The code names the part that noticed
An E9 is rarely the thermostat and an EA is rarely the board. On a Worcester the code names the component reporting the fault, not the one that failed, which is why so many of these get repaired twice. Read us the code and the cause code and we will tell you which is which.
The model is on a data badge behind the front panel, and with Worcester the letters after the number matter more than the number itself.
The number is the output in kilowatts. The letters are the type, and that is the part that decides which half of your system an engineer is looking at.
If your badge carries Si or Ri you have stored hot water somewhere in the house, and the cylinder is as likely to be the fault as the boiler is.
Greenstar i and Greenstar Si Compact are on more London walls than anything else Worcester make, usually in the 25 to 30 kilowatt range and usually in a kitchen cupboard.
Greenstar CDi Classic is the older higher output range, and the 30CDi and 42CDi turn up constantly in larger houses. Parts are still current.
Greenstar 8000, sold as Life and Style, and Greenstar 4000 are the current generation. They report faults differently from everything above, which matters when you look up a code.
Greenstar Ri and CDi Highflow are the ones with no display. The Highflow has an internal store, so it behaves like neither a combi nor a system boiler and gets misdiagnosed as both.
Worcester guarantees run for a fixed term from the date of installation, and the term is routinely longer than people remember agreeing to. The condition is normally that the boiler was fitted by an accredited installer and has been serviced every year since.
Here is the part that catches people out: the guarantee is registered against the appliance, not against you. Buy a house with a five year old Greenstar in it and the remaining cover often comes with it, and almost nobody thinks to check.
You need the serial number off the data badge. Check before you spend anything, including with us. If you are inside the guarantee we will say so and stand down.
London is a hard water city almost everywhere, and that is the single biggest difference between repairing a Greenstar here and repairing one in Manchester or Glasgow.
Chalk is the reason. The Thames and the Lea both run through it in the Chilterns and the North Downs before the water reaches your tap, and the result is roughly 277 milligrams of calcium carbonate per litre, ranging from about 250 to over 350 depending on the district. Inside a combi that means one thing: the plate heat exchanger furs up faster than the manual's service intervals allow for.
It is the same story in Hampstead and Belsize Park as it is in Sutton and Cheam. The water is hard, the plate heat exchanger scales, and the only question is whether anybody checks it before condemning the boiler.
Hardness is not uniform, and it does not follow borough boundaries. It varies by supply zone and can change over a short distance, so your supplier publishes a figure for your own postcode and it is worth reading before anybody guesses.
Scale drops out of solution faster the hotter the water gets. A combi set to deliver taps at 65 degrees furs up its plate heat exchanger noticeably faster than one set to 50, which is still hot enough to scald. Turning that dial down costs nothing and is the most effective thing a householder in a hard water area can do. This applies to the tap setting, not to a cylinder, which must reach 60 degrees for safety.
Stored hot water is normal in larger London houses, and no combi replaces it whatever the output figure says.
A great many London firms will only touch combis, which is awkward in a city with this much older housing stock. A Worcester system or heat only boiler feeds a separate cylinder carrying its own thermostat, immersion element and, where it is unvented, its own safety devices. Two appliances rather than one, which is why no hot water so often turns out to have nothing to do with the boiler at all.
The cylinder sensor lives in a pocket on the tank. If it fails or works loose the boiler stops heating the cylinder while every radiator stays warm, which is the single clearest sign the fault is not in the appliance.
The motorised valve sends the heat to the radiators, the cylinder or both. When its motor or microswitch goes you get heating with no hot water, hot water with no heating, or both at once, and the head usually changes without draining anything.
The immersion element furs up in London water and then either trips out or stops working. Test it before condemning a tank, because the element is a fraction of the cost. In larger houses across Dulwich we generally fit a scale reducer on the same visit.
Because an unvented cylinder holds mains pressure, it carries a set of safety devices: an expansion vessel, a pressure reducing valve, an expansion relief valve and a temperature and pressure relief valve, all discharging through a tundish. Water at the tundish is the system reporting that one has failed, and capping it is never the answer.
That work is notifiable and requires G3 as well as Gas Safe registration. We hold both, so the appliance and the cylinder are diagnosed on the same visit rather than across two. It is why our unvented cylinder repair is not farmed out to somebody else.
Removing a cylinder to reclaim an airing cupboard is the decision we are asked to undo more than any other. However large the output figure, a combi heats water as it passes rather than storing it, so it cannot serve two showers at once. With three bathrooms the right answer is almost always to keep stored hot water, and to replace an ageing cylinder rather than lose it.

We would sooner keep a boiler running than sell you a new one. The age on the label does not settle this. The failed component does.
| What has failed | Under 8 years | 8 to 14 years | 15 years and older |
|---|---|---|---|
| Flame sensing electrode, ignition lead | Repair | Repair | Repair if parts exist |
| Condensate siphon, sensors | Repair | Repair | Repair if parts exist |
| Expansion vessel, pump head | Repair | Repair | Repair |
| Hot water turbine, plate heat exchanger | Repair | Repair | Repair if the part is still made |
| Fan | Repair | Repair | Depends on the rest of the boiler |
| Gas valve | Repair | Depends on the rest of the boiler | Replace |
| Circuit board | Guarantee claim if registered | Borderline, we will be straight with you | Replace |
| Main heat exchanger | Guarantee claim if registered | Usually replace | Replace |
Nothing is obsolete at this age, and a failure here is a single part rather than a boiler wearing out. An electrode, siphon, turbine or pump head on a six year old Greenstar is a repair, without qualification.
Find the serial number and ask about guarantee cover before anybody quotes you, including us. Worcester terms run for a fixed number of years from installation and a boiler that feels too old to be covered often is not.
If somebody offers you a new boiler at this age, ask which single part has failed and what that part costs on its own. The gap between the two answers is usually the whole conversation.
Still a clear repair: electrode, fan, pump head, condensate siphon, expansion vessel, hot water turbine. These are ordinary wear items and they say nothing about the condition of the rest of the boiler.
The conversation changes with a main heat exchanger, or a second significant failure inside a year. At that point the arithmetic favours replacing the boiler, and the question is not only what has gone today but what goes in the next two winters.
A Greenstar that has had one electrode and is otherwise dry, quiet and holding pressure is a boiler worth keeping. They were built to be kept.
Past this point availability starts to take over from cost. A CDi Classic at fifteen is often still a straightforward repair, because the wear parts on that range are still made, and that is worth establishing before anybody writes the boiler off.
The exception is the older Highflow, where the internal store is the expensive part and the one most likely to have gone. A store is not an economic repair on a boiler of that age, and anybody telling you otherwise is not doing you a favour.
We will tell you whether the part still exists before you spend anything on a diagnosis. What actually moves the number is set out in our guide to repair and replacement costs.
Boiler problem? We're here 24/7
Emergency boiler repairs across London, north and south of the river
Call 0203 868 6134London, north and south of the river. These are the districts we work in most.
These are where we work most, not a boundary. An engineer attends anywhere in north London and south London. Tell us where you are and we will say plainly when we can get to you.
If you smell gas: do not touch any switches. Open the windows, leave the property, then call the National Gas Emergency Service on 0800 111 999. That line is free and open 24 hours. Call them before you call us.
If a carbon monoxide alarm is sounding: get everyone out immediately, then call 999 if anyone feels unwell. Do not go back in until the property has been ventilated and checked.
If the boiler locks out repeatedly: try one reset. If it locks out again straight away, stop. Repeated resets hide a fault that is still there, and on a gas appliance that is not a risk worth taking.
Under the Gas Safety (Installation and Use) Regulations 1998, only a Gas Safe registered engineer may work on gas appliances. Never open the boiler casing yourself.
EA means the boiler could not detect a flame through its ionisation probe, so it shut the gas off and locked out. The number beside it decides the repair. EA 227 means no flame was detected after ignition, which usually points at the flame sensing electrode and its lead. EA 229 means a flame was established and then lost, which points at gas pressure, the gas to air ratio or the flue rather than at a part. Check whether other gas appliances work, and in winter check the condensate pipe outside for ice.
Because the pair is the diagnosis. Greenstar models show a letter code and a cause code, and the letters alone are often too broad to act on. EA covers several different failures and only the number separates them. When you call anybody about a Worcester, read out both. If your model shows a number on its own, or a letter on its own, that tells an engineer which generation of boiler you have before you have said anything else.
E9 means the safety temperature limiter has tripped because the water went past its limit. It is almost always circulation rather than the burner: sludge, a closed or seized valve, a tired pump or trapped air, so the boiler makes heat faster than the system carries it away. Replacing the limiter rarely helps, because it is the part reporting the problem rather than causing it. getting the sludge out addresses the cause where a component swap usually does not.
You can top it up. Newer models show H07 for low pressure and older ones simply refuse to fire, so check the gauge before assuming the worst. Fill through the loop until it reads between 1 and 1.5 bar cold, then reset once. What you cannot fix is why it dropped: once a year is normal, every few weeks means a leak, and every few days means the expansion vessel has lost its charge. No heat with normal pressure is an emergency boiler repair instead.
Usually not, and the pattern tells you which fault it is. Water that is steadily lukewarm and never gets properly hot is a scaled plate heat exchanger. Water that gets properly hot some of the time and then drops away is the flow turbine, the small sensor that tells the boiler a tap has opened. Both are one part on a boiler that is otherwise sound. Having it serviced once a year catches the scaling while flushing is still an option.
The data badge is behind the front panel. The number is the output in kilowatts and the letters are the type: i is a combi, Si is a system boiler, Ri is heat only and CDi is the higher output range. If yours reads Si or Ri you have stored hot water somewhere in the house. Read us the serial from the badge when you ring, because the serial number on it is what an engineer needs to order the right variant and what you need to check the guarantee. We repair all the major makes.
Usually yes. The wear parts on the CDi Classic are still made, so a fifteen year old one is often a straightforward repair rather than a write-off. Guarantee cover matters here: it runs for a fixed term from installation and it stays with the appliance when a house changes hands, so read us the serial when you ring and we can tell you where you stand. The exception is the older Highflow, where the internal store is the expensive part. See our boiler replacement page.
It depends on the part, and that is not evasion. A price given before anybody has asked what your boiler is doing is invented. The figure comes from three things, the part, whether it is in stock on the van, and the labour time. On a Worcester the cause code beside the letters usually tells us which part before anybody attends. The rate is agreed beforehand and parts we fit are guaranteed for a year, so nothing is carried out on the assumption that you will approve it afterwards. There is no charge for telling you a repair is not the right call. What actually moves the number is set out in our guide to repair and replacement costs.
Worcester and Bosch are the same company, so a Bosch badged boiler and a Greenstar share most of their parts and most of their fault codes.
No gas supply? Plenty of London flats run without one, and we also cover electric boiler repair.
An E9 is rarely the thermostat. Have the code, the cause code beside it and the model from the badge, and we will tell you which part actually failed rather than which one noticed.
Gas Safe registered. Unvented cylinder qualified. Parts guaranteed for a year. Covering London, north and south of the river, 24 hours a day.